Cover Image of Download Modbus Monitor Advanced  APK

4/5 - 41 votes

ID: com.Bhavan.Galex

  • Author:

  • Version:

    Varies with device

  • Update on:

Download APK now

The description of Modbus Monitor Advanced


This Modbus App has three Apps in one. Android Modbus Master/Client/Poll, Slave/Server/Simulator, and Sensors Server. This simple to use utility is simple has many advanced features unmatched even by PC-based standards.

> Choose 4 Interfaces: (1) Bluetooth SPP & BLE, (2) Ethernet, (3) Wi-Fi, (4) RS232/485 USB Serial ports (USB OTG capable devices)

> Choose from 8 Modbus Protocols: Modbus TCP, Enron/Daniels TCP, Modbus RTU over TCP, Modbus UDP, Modbus RTU over UDP, Modbus TCP Slave/Server, Modbus RTU, Modbus Serial ASCII

> Explore Sensor Server: Remotely monitor mobile device's sensors using Modbus Protocol (sensors such as Gyro, GPS, *Cell Phone Tower, etc.) remotely with built-in Modbus Sensor Server

> Log data to ThinkSpeak platform: Graphically log and view data on ThinkSpeak cloud.

> Log data Google Sheets: Use phone sensor (or any polled data) and log values straight into your private Google Spreadsheet in the cloud!!! The same Google Sheet can be used to centrally log values from different mobile devices into one Google Sheet (one file per device or all devices).

> Easy to use Import/Export: Import in CSV format. Export data to CSV format every second, minute, or hour. Export configuration data via email or log to ThinkSpeak or Google Sheets Cloud platforms

> Modbus Functions: FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, Write Auto Pick

> Simple 6 digit Input Modbus Address input

> Push to write pre-set value

> Convert Modbus Integer Values to Text (Coded Message or Status Converter)

> Data Conversion: Unsigned, Signed, Hex, Binary, Long, Double, Float, String, BCD formats, Unix Epoch Time, PLC Scaling (Bipolar/Unipolar Analog ADC value conversion)

> Pro Tuning Options: Interval, Inter-Packet Delay, Link-Timeout, Actual RX/TX Counts

> Bluetooth Requirement
1. Your device must have Bluetooth Radio that supports SPP profile (RFCOMM Secure or Insecure)
2. See "ModbusMonitor.com" or email [email protected] for help
3. See below for hardware requirements

> USB-to-Serial Port Requirement, USB OTG Serial Ports>> RS232/422/RS485
Your device must meet all of the THREE requirements.

1. Your device must be Android version 3.2 or newer
2. Your device must support USB Host or OTG interface
3. Your USB-to-Serial Port dongle must contain one of following chipsets: >FTDI [FT230X, FT231X, FT234XD, FT232R, or FT232H], Prolific [PL2303HXD, PL2303EA, or PL2303RA], SiLab [CP210x], QinHeng CH34x
4. RS485: Tested with "no echo" setting turned ON.

More: www.modbusmonitor/guide/serialport

> Feedback
www.ModbusMonitor.com contains an online form in the "Feeback" section for those interested in providing constructive feedback or feature requests.

> Help
- www.modbusmonitor.com/help
- email: [email protected]
Show more
  • Category

    Tools
  • Get it on:

    Go Google Play com.Bhavan.Galex
  • Requirements:

    Android Varies with device+

Modbus Monitor Advanced Varies with device APK for Android Varies with device+

Version Varies with device for Android Varies with device+
Update on 2022-11-17
Installs 1.000++
File size 0 bytes
Permissions view permissions
What's new Added CDC Driver for Arduino and more
Updated Permissions required to support newer Android OS
Updated Moxa USB first connection issues on some devices and Modbus Console
Removed Google Spreadsheets for compatibility (until futher notice)

Hit APK
Show more